♊QV pipeline rapid detection instrument field operation process:
1. Check whether the environment inside the well meets the safety requirements of the product.
2." style="box-sizing: border-box;background: transparent">Periscope for pipeline inspection Pay attention to whether there is a high voltage line nearby, so as to avoid danger when the telescopic bar rises or falls.
3. Connect and debug the equipment to ensure that the product is normal before it can be used.
(1) confirm the safety and slowly deliver the equipment to the well, keep the telescopic bar basically perpendicular to the ground, keep the distance from the water surface no less than 150mm, and keep the camera as far as possible in the center of the pipeline.
(2) according to the image situation, the camera can be adjusted to the best position.
(3) adjust the pitch angle of camera assembly to the best angle according to the image angle.
(4) check the light to the best position according to the image effect.
(5) the camera must be shifted 90 degrees to move laterally to prevent the collision.
(6) check and shut down.
(7) remove the camera assembly outside the well, remove the telescopic bar, clean the water and dirt of the camera assembly shell, keep the equipment clean and dry, and protect the cover at the front end, so as not to damage the internal precision parts.
(8) after cleaning, remove cables and batteries and equipment.